Fluke 1760 Basic Three Phase Power Quality Recorder Topas Price in BD
$46.3
$71.3
Class-A compliance for the most demanding power quality tests The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium- and low-voltage networks, this power quality monitor provides the flexibility to customize thresholds, algorithms, and measurement selections. The 1760 power recorder captures the most comprehensive details on user-selected parameters. Applications Detailed disturbance analysis – Perform high-speed transient analysis and uncover root cause of equipment malfunction for later mitigation and predictive maintenance. The fast transient option, with its 6000 V measurement range, allows capture of very short impulses such as lightning strikes. Class-A quality-of-service compliance – Validate incoming power quality at the service entrance. Thanks to Class A compliance, the Fluke 1760 allows undisputable verification. Event correlation at multiple locations – Utilizing GPS time synchronization, users can quickly detect where a fault occurred first, either inside or outside the facility. Galvanic separation and DC coupling – Allows complete measurements on dissimilar power systems. For example troubleshoot UPS systems by simultaneously recording the battery voltage and power output Power quality and power load studies – Assess baseline power quality to validate compatibility with critical systems before installation and verify electrical system capacity before adding loads. Overview of Measurement Functions Statistical Evaluation Power quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI Continuous Recording Fluke 1760 records rms values together with corresponding minimum and maximum values for: Voltage Current Power P, Q, S Power Factor kWh Flicker Unbalance Frequency Harmonics/Interharmonics continuously with the following time aggregations: Day 10 min Free Interval, e.g.: 15 min, 2h Triggered Recordings rms: Aggregation time is adjustable between 10 ms (1/2 cycle), 20ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles). Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency. Basic aggregation for harmonics and interharmonics is 200ms Oscilloscope: Sample rate is 10.24 kHz for all 8 channels Fast Transients: Sample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients Mains Signalling Phases and N-conductor, Voltage and current Online Mode Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events. General Data Intrinsic uncertainty refers to reference conditions and is guaranteed for two years Quality system developed, manufactured as per ISO 9001: 2000 Environment conditions Operating temperature range: 0 °C to 50 °C; 32 °F to 122 °F Working temperature range: -20 °C to 50 °C; -4 °F to 122 °F Storage temperature range: 20 °C to 60 °C; -4 °F to 140 °F Reference temperature: 23 °C ± 2 K; 74 °F ± 2 K Climatic class: B2 (IEC 654-1), -20 °C to 50 °C; -4 °F to 122 °F Max. operating altitude: 2000 m: max. 600 V CAT IV*, power supply: 300 V CAT 2000 m: max. 600 V CAT IV*, power supply: 300 V CAT III 5000 m: max 600 V CAT III*, power supply: 300 V CAT II * depending on sensor Reference conditions Environment temperature: 23 °C ± 2 K ; 74°F ± 2 K Power supply: 230 V ± 10 % Power frequency: 50 Hz / 60 Hz Signal: declared input voltage Udin Averaging: 10 minute intervals Housing insulated, robust plastics housing EMC Emission: Class-A as per IEC/EN 61326-1 Immunity: IEC/EN 61326-1 Power supply Range: AC: 83 V to 264 V, 45 to 65 Hz DC: 100 V to 375 V Safety: IEC/EN 61010-1 2nd edition 300 V CAT III Power consumption: max. 54VA Battery pack: NIMH, 7.2 V, 2.7 Ah In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user. Display Fluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer. Power LED: • Permanent light: normal power supply from mains. • OFF: supply via internal accumulator in case of a power failure. Channel LEDs 3-color LEDs per channel for: • overload condition • under load condition signal level in nominal range Data memory 2 GB Flash memory depending on model Memory model Linear Interfaces Ethernet (100MB/s), compatible to Windows® 98/ME/NT/2000/XP RS 232, external modem via RS 232 Baud rate for RS 232 9600 Baud to 115 kBaud Dimensions 325 mm x 300 m x 65 mm; 2.8 x 11.8 x 2.6 in. (H x W x D) Weight appr. 4.9 kg; 10.8 lbs. (without accessories) Warranty 2 years Calibration interval 1 year recommended for Class-A, otherwise 2 years Signal Conditioning Range for 50 Hz systems 50 Hz ± 15 % (42.5 Hz to 57.5 Hz) Range for 60 Hz systems 60 Hz ± 15 % (51 Hz to 69 Hz) Resolution 16 ppm Sampling frequency for 50 Hz power frequency 10.24 kHz, The sampling rate is synchronized to mains frequency. Uncertainty for frequency measurements < 20 ppm Uncertainty of internal clock < 1s / day Measurement intervals Aggregation of the interval values as per IEC 61000-4-30 Class-A Min-, Max-values: Half cycle, e.g.: 10 ms rms values at 50Hz Transients: Sample rate 100 kHz to 10 MHz per channel Harmonics as per IEC 61000-4-7:2002: 200 ms Flicker as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt) Measurement Inputs Number of inputs 8 galvanically isolated inputs for voltage and current measurements. Sensor safety up to 600 V CAT IV depending on sensor Basic safety 300 V CAT III Nominal voltage (rms) 100 mV Range (peak value) 280 mV Overload capacity (rms) 1000 V, continuously Voltage rise rate max. 15 kV / µs Input resistance 1 MΩ Input capacitance 5 pF Input filter Each channel is equipped with a passive low-pass filter, an anti-aliasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse. The filters protect against voltage transients and limit the signal rise rate, reduce high frequency components and especially the noise voltage above half the sampling rate of the A/D converter by 80 dB, thus achieving very small measuring errors in an exceptionally large amplitude range. This is also valid under extreme operating conditions like transient voltages at the output of converters. Uncertainties Uncertainty at reference conditions Uncertainty including the voltage sensors is in compliance with IEC 61000-4-30 Class-A. All voltage sensors are suitable for DC up to 5 kHz With Sensor 1000 V 0,1% at Udin = 480 V and 600 V P-N Sensor 600 V 0,1% at Udin = 230 V P-N Intrinsic uncertainty for harmonics Class I as per EN 61000-4-7:2002 Reference conditions 23 °C ± 2 K < 60 % rH; 74 °F ± 2 K < 60 % rH Warmed up instrument > 3h Power supply: 100 V to 250 V ac Temperature drift 100 ppm / K Aging < 0.05 % / year Common mode rejection > 100 dB at 50 Hz Temperature drift Change of amplification through temperature: < 0.005 %/K Aging Change of amplification due to ageing: < 0.04 %/year Noise Noise voltage, input short-circuited: < 40 µV DC ± (0.2% rdg 0.1% sensor) Power Measurement/Power Quality Analyzer Template Type (Power Quality) 3 Phase Maximum Voltage AC 1000 V Maximum Voltage DC 1000 V True Power / Work ( W) Yes Apparent Power (VA) Yes Reactive Power (VAR) Yes Measurement Frequency (Power Quality) 50 Hz, 60 Hz Display (Power Quality) Digital Alarms Yes Transient Capture Yes Displays Waveform Yes Energy Yes Phasor Diagrams No Power Factor (Power Quality) Yes Harmonics Yes Maximum Harmonics Range 200 Current Clamps Included No Class A Compliant Yes Crest Factor Yes CAT Rating IV Country of Origin: Germany
Electric Item